Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 582-587, 2022.
Article in Chinese | WPRIM | ID: wpr-924000

ABSTRACT

Objective @#To discuss and summarize the preventive measures and treatment methods for aspiration/ingestion during dental procedures.@*Methods @# One case of aspiration during an implant operation was reported, and the literature on aspiration/ingestion during oral procedures was reviewed.@*Results@#An implant screwdriver accidentally slipped into the mouth of the patient during implant surgery. The patient experienced no obvious discomfort except a few coughs. The surgeon and assistant paused the procedure immediately to search for the screwdriver, but it was not found. The patient declared that there was no special abnormality, such as breathing disorder or chest distress, so we considered that the foreign body was ingestion. After the implant surgery was completed, no foreign body was found in the stomach via gastroscopy. Chest X-ray and CT showed a dense metal shadow in the lower lobe of the left lung. Under local anesthesia, bronchoscopy and biopsy forceps were used by respiratory physicians to clip out the foreign body. After removal of the foreign body, the patient had no obvious discomfort but a slight cough. Cephalexin and metronidazole were given for three days to prevent infection. Three days later, the patient had no complaints of respiratory discomfort. After reviewing the literature, we found that the operation should be paused immediately after aspiration/ingestion occurs during dental procedures and that the dental chair should be laid down to prevent the foreign body from descending deeper, which may increase the difficulty of removal and cause gastrointestinal and respiratory tract injury. The position of the foreign body should be determined by imaging examination, and the corresponding means to remove the foreign body should be performed.@*Conclusion @# Patients may have no obvious symptoms after aspiration/ingestion during dental procedures, and the foreign body can be removed after imaging examination.

2.
China Journal of Orthopaedics and Traumatology ; (12): 622-627, 2021.
Article in Chinese | WPRIM | ID: wpr-888327

ABSTRACT

OBJECTIVE@#To develop a universal screwdriver for sealing the end of the central hole of the femoral interlocking intramedullary nail, so as to shorten the operation time of the tail cap implantation of the intramedullary nail and improve the accuracy of implantation.@*METHODS@#Total 77 patients with intertrochanteric fractures underwent femoral interlocking intramedullary nail (FIIN) surgery from June 2018 to June 2019. There were 28 males and 49 females, aged 55 to 80 (76.22± 7.32) years old, and course of disease was 20 to 40 h. All patients were divided into universal screwdriver group (39 cases) and ordinary screwdriver group (38 cases) according to whether the self-developed universal screw was applicable during the operation. The blood loss during tail cap implantation, the time of tail cap implantation, the success rate of one-time implantation, and the postoperative curative effect were compared between two groups.@*RESULTS@#All patients were followed up for 12 to 36 months, with an average of(20.00±6.38) months. The bleeding volume and the time of tail cap implantation in the universal screwdriver group were significantly lower thanthose in the ordinary screwdriver group (@*CONCLUSION@#The universal screwdriver is easy to operate during the operation when using the cap of the femoral intramedullary nail, the operation time is shortened, the amount of bleeding is reduced, and the treatment effect is satisfactory.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Bone Nails , Femoral Fractures , Fracture Fixation, Intramedullary , Fracture Healing , Hip Fractures/surgery , Retrospective Studies , Treatment Outcome
3.
The Journal of Korean Academy of Prosthodontics ; : 695-703, 2000.
Article in Korean | WPRIM | ID: wpr-151151

ABSTRACT

The purpose of this study was to evaluate the effects of fabrication and tightening methods of gold cyliner on the preload of the standard abutment. Three linear strain gauges (KFR-02N-120C1-23, Kyowa, Japan) were mounted longitudinally on the 5.5mm Standard abutment (Nobel Biocare, Sweden) and three kinds of gold cylinders such as, as-received gold cylinder, gold cylinder after casting, and plastic cylinder after casting with type IV gold alloy were connectedd over the top of the standard abutment. Two kinds of tightening methods, such as manual torque with handheld screwdriver and electronic torque using Electronic torque controller were used to generate preload on the abutment. The result were as follows 1. The preload generated by tightening cast plastic cylinder with handheld screw driver, was the lowest among the six groups. 2. The preload generated by cast plastic cylinder was lower than those by gold cylinders regardless of the tightening methods. 3. The electronic torque controller produced higher torque values than the handheld screwdriver.


Subject(s)
Alloys , Plastics , Torque